CALL US
0086-371-60922096

MIXERS FOR QUALITY CONCRETE IN ALL SLUMP RANGES

Volumetric Mixer Trucks Should Be Banned!

Nov 18, 2015 · Last year, the government began an investigation into whether volumetric concrete mixers were road legal. It wasn't just volumetric mixers, rather it looked at all vehicles that blurred the lines

Learn More

Nitpicking Slump-Test Results| Concrete Construction Magazine

Oct 01, 2000 · To apply this, a different operator might test the concrete first measured at a 5 1/4-inch slump and obtain a slump of somewhere between 4 1/2 inches and 6 inches. Due to the limited slump range and relatively low slump on which the repeatability limit is based, the actual precision might be lower and result in a repeatability limit even

Learn More

REVISION OF CONCRETE PRODUCTION STANDARD NZS 3104 …

the concrete can be specified in a broad slump class such as S3 (90-170mm) rather specifying a target slump of 100mm with a tolerance of 30mm. A possible unintended consequence of this approach is that designers who would have previously specified a target slump of 100mm will select slump class S2 with a slump range of 40-110mm.

Learn More

Guide To Concrete Workability | Concrete Slump | Concrete2you

Stetter pan mixers guarantee production of quality concrete in all slump ranges as they mix intensively, thanks to short exchange paths both horizontally and vertically. Therefore, with Stetter pan mixers you produce homogenous concrete with short mixing times and low energy input.

Learn More

SCHWING-STETTER ALWAYS CLOSE TO THE CUSTOMER. MIXERS …

Concrete for Durable Floors| Concrete Construction Magazine

Learn More

Vertical Shaft Concrete Mixer, Planetary Concrete Mixer

Vertical shaft concrete mixer is a special concrete mixer, which can mix concrete alone or use in concrete batching plant as a mixer. The mixing shaft is vertical and it has a wide range of uses, not only for mixing ordinary commercial concrete, dry concrete and precast concrete, but also for mixing glass, ceramics and refractory materials.

Learn More

One-Stop pump truck Depot From Leading Sellers - Alibaba.com

Transfer Pump Oil Transfer Pump Fuel Delivery Pump SPA/H2206-502 1311H0592/A07971 For WD615 ZL50 Zoomlion Used Cement Transfer Pump Truck Mounted Concrete Pump India Price. $50,000.00-$150,000 Your search for high quality and adept concrete transfer pump ends with the product line at Alibaba.com. Offered by the leading and prominent

Learn More

What is Concrete Slum Test? - Concrete Information

Concrete Slump Test Procedure, Applications & Types of Slump

Learn More

SECTION 601 - CONCRETE

concrete placed in the work. Make satisfactory repairs to any truck mixers that will not discharge concrete within the specified slump and air content ranges before using them. Attach to each truck mixer a metal plate stating the manufacturer's capacities in …

Learn More

Concrete Testing Equipment, Non-Destructive Test

Humboldt provides a full range of fresh concrete testing equipment for construction jobs of all sizes, in accordance with ASTM C321 and other standards. The H-2784 Super Air Meter – This high-quality air meter measures air void spacing and air volume of fresh concrete to help users better understand the freeze-thaw durability of fresh concrete.

Learn More

Code and Standards Requirements For Acceptance Testing

WWW. NRMCA.ORG Scope of Testing • Samples obtained in accordance with ASTM C172 • Point of delivery from transportation unit (or mixer) • Other sampling methods should be defined • Fresh Concrete tests • Slump or slump flow – tolerances in ASTM C94; ACI 117 • Air content – tolerance ±1.5% • Temperature – limits in specifications • Density – typically no limits unless

Learn More

What is concrete slump test? step-by-step procedure

Concrete Slump Test. The concrete slump test is an on-the-spot test to determine the consistency as well as workability of fresh concrete. This test plays a vital role in ensuring immediate concrete quality in a construction project. It is used almost in every construction …

Learn More

Concrete for Durable Floors| Concrete Construction Magazine

Nov 28, 2007 · With a properly graded aggregate system and the cement amounts previously mentioned, look for a water-cement (w/c) ratio of 0.50 to 0.54. Concrete slump always is a topic of conversation and controversy. For floors, a slump range of 4 to 5 inches works well. Many flooring contractors like to place concrete in this slump range.

Learn More

What is concrete slump test? step-by-step procedure

Concrete Slump Test. The concrete slump test is an on-the-spot test to determine the consistency as well as workability of fresh concrete. This test plays a vital role in ensuring immediate concrete quality in a construction project. It is used almost in every construction …

Learn More

REVISION OF CONCRETE PRODUCTION STANDARD NZS 3104 …

the concrete can be specified in a broad slump class such as S3 (90-170mm) rather specifying a target slump of 100mm with a tolerance of 30mm. A possible unintended consequence of this approach is that designers who would have previously specified a target slump of 100mm will select slump class S2 with a slump range of 40-110mm.

Learn More

Hot-Weather Concreting, Chapter 13 - Cemstone

mixed concrete is increased from 10°C to 38°C (50°F to 100°F), about 20 kg/m3 (33 lb/yd3) of additional water is needed to maintain the same 75-mm (3-in.) slump. This additional water could reduce strength by 12% to 15% and mixed concrete notes in some situations difficulty may be encountered when concrete temperatures approach 32°C (90°F).

Learn More

Slump adjustment is a fact of life for concrete

the same slump the concrete had at the lower tempera t u r e. Mi x i n g . To achieve a uniform c o n c r ete batch, ASTM C 94 re q u i re s a minimum of 70 to 100 re vo l u t i o n s at mixing speed. Because it's diffi-cult to obtain uniform concrete in an overloaded mixer, the volume of …

Learn More

SECTION 409 PORTLAND CEMENT CONCRETE PAVEMENT

**The nominal slump in inches shall be 3 inches, the maximum slump shall be 3-1/2 inches. When the slump of concrete is found to exceed the nominal slump, the mixture shall be adjusted as directed by the Engineer to reduce slump to a value within the specified range. Four slump tests will be considered sufficient to determine nominal slump.

Learn More

Concrete Slump Testing: Why Bother? - Braun Intertec

Mar 21, 2019 · The slump test has a long history of use in the construction industry and still has a significant role to play in producing quality concrete. During concrete placements, regardless of their size, there is a need for a quick, basic, fundamental, and repeatable test method to accept or reject concrete deliveries.

Learn More

Automated Measurement and Control of Concrete Properties

concrete is mixed in different truck mixers. VERIFI system was able to adjust and maintain the slump at specified target slumpthe until delivery by adding water or high-range water reducer (HRWR) The average and standard . deviation of difference between the slump of …

Learn More